calendar, a clock and pills on a pink background

EUDAMED Registration for Legacy Devices Without a Basic UDI-DI (EUDAMED-DI)

How the EUDAMED DI and EUDAMED ID work, and how to assign them correctly before the 28 November 2026 deadline?

Devices registered in the EUDAMED need a device identifier. 

For MDR and IVDR devices, these are the Basic UDI-DI and the UDI-DI. Legacy devices are different. The UDI obligations of the MDR and IVDR do not apply to them, and in EUDAMED a legacy device is usually not identified by a Basic UDI-DI.

Legacy devices that are still placed on the market must nevertheless be registered by 28 November 2026, as explained in our article on the EUDAMED November 2026 deadline. To make this possible, EUDAMED uses two substitute identifiers: the EUDAMED DI and the EUDAMED ID.

Obelis explains what these identifiers are, how to assign them, and which choices made now will save you work when your devices move to the MDR or IVDR.

Why Legacy Devices Do Not Have a Basic UDI-DI

Legacy devices are not required to carry a UDI, but they are still subject to the registration requirements of the MDR and IVDR. To allow registration without a UDI, the Medical Device Coordination Group adapted the design of EUDAMED in MDCG 2019-5.

Regulation deviceLegacy deviceRole
Basic UDI-DIEUDAMED DI (starts with “B-“)Main access key to the device record in EUDAMED
UDI-DIEUDAMED ID (starts with “D-“), or an existing UDI-DIIdentifies the specific device

Two Ways to Identify a Legacy Device in EUDAMED

When you register a legacy device, EUDAMED first asks whether a UDI-DI has already been assigned to it. Every legacy device has a EUDAMED DI; its second identifier is either the existing UDI-DI or a EUDAMED ID, never both.

Route 1: the device already has a UDI-DI

If a UDI-DI has already been assigned to the legacy device, you can use the existing UDI-DI to register the device in EUDAMED.

Route 2: the device has no UDI-DI

If no UDI-DI exists, the manufacturer assigns a EUDAMED DI. The corresponding EUDAMED ID has exactly the same value, with the prefix “D-” instead of “B-“.

Certificate and Device Data for a Legacy Device

Notified bodies do not register Directive certificates in EUDAMED, so MDCG 2019-5 requires the manufacturer to enter these details when registering the legacy device. 

Planning Ahead: Linking Legacy Devices to MDR and IVDR Devices

When the equivalent of a legacy device becomes compliant with the MDR or IVDR, EUDAMED allows linking a Regulation Device (once the device is fully IVDR compliant) with the correspondent legacy device and it will perform this linking automatically when both have the same UDI-DI. The link will be made at the level of the UDI-DI.

Under the Commission’s Q&A on the gradual roll-out of EUDAMED, a legacy device does not need its own registration if “the same device” is already registered as a Regulation device. Legacy devices may also carry a UDI-DI. 

Four Steps Before 28 November 2026

  1. Register your legacy devices that are still placed on the EU market on or after 28 May 2026.
  2. Check certificate and device data against your Directive certificates, labelling and instructions for use.
  3. Register in good time, through the user interface, XML bulk upload or machine-to-machine exchange, and leave room to correct validation errors before the deadline.

How Obelis Can Help

As your EU Authorised Representative, Obelis can support you with:

  • deciding, device by device, whether to register with an existing UDI-DI or a EUDAMED DI;
  • building a consistent EUDAMED DI numbering scheme based on your SRN;
  • checking certificate, labelling and device data before submission;
  • completing your EUDAMED registration and linking legacy devices to their MDR or IVDR successors.

Sources

  1. Medical Device Coordination Group (2019). MDCG 2019-5 – Registration of legacy devices in EUDAMED. Retrieved on 2 November 2026 from https://ec.europa.eu/docsroom/documents/34922
  2. European Commission (2021). Management of Legacy Devices https://health.ec.europa.eu/document/download/4699ad8d-bf2c-4303-bd25-10e26770c8b1_en
  3. European Commission. EUDAMED Information Centre https://webgate.ec.europa.eu/eudamed-help/en/actor/topics-by-actor/eu-manufacturer/registering-legacy-devices/eudamed-di-identification-information.html 
  4. European Commission (2026). EUDAMED user guide https://webgate.ec.europa.eu/eudamed-help/en/files/Legacy%20Devices%20-%20user%20guide.pdf
  5. European Commission. EUDAMED Information Centre https://webgate.ec.europa.eu/eudamed-help/en/search-by-module/devices/legacy-devices/basic-concepts/identification-details/generation-of-identification-details-for-a-legacy-device-when-a-udi-di-does-not-exist.html
  6. European Commission (2024). https://health.ec.europa.eu/latest-updates/gradual-roll-out-eudamed-qas-practical-aspects-related-implementation-regulation-eu-20241860-2024-11-21_en 

Compliance Insights You Might Find Useful

Stay Updated on Career Opportunities

Careers at Obelis

Leave a Reply

Your email address will not be published.

Share This

Copy Link to Clipboard

Copy